Cryogenic Grinder JXFSTPRP-CLN

型号:JXFSTPRP-CLN

品牌:Shanghai Jingxin

规格:Set

产品简介:Shanghai Jingxin JXFSTPRP-CLN Cryogenic Grinder is a fast and efficient, multi-test tube consistent system. It can extract and purify the original DNA, RNA and protein from any source .

Product description: Main overview:

Shanghai Jingxin JXFSTPRP-CLN Cryogenic Grinder is a fast, efficient and refrigerated grinding system. It can grind, pulverize, and break the cell walls of soil, plant and animal tissues/organs, bacteria, yeast, fungi, spores, and paleontological specimens in a very short time. Widely used in life science, medicine, biochemistry, environment, geology, agriculture, forestry, quality inspection, materials and other fields.

JXFSTPRP-CLN Product principle:

Put the sample and grinding ball into the grinding machine (with grinding jar or centrifuge tube/adapter), under the action of high frequency swing, the grinding ball collides and rubs back and forth in the grinding machine at high speed, and the sample can be completed in a very short time Grinding, crushing, mixing and cell wall breaking.

Main functions and technical indicators:

1. Extract nucleic acid/protein

Cryogenically ground samples can effectively inhibit nucleic acid degradation and retain protein activity.

2. Analysis of medicinal components

There are often significant differences between isomers of active pharmaceutical ingredients, and cryogenic milling prevents the molecules from degrading due to stress and heat.

3. Reduce sample volatilization

Cryogenic grinding can significantly reduce the volatilization of the sample and preserve the content of the sample components more completely.

4. Grinding tough/hard samples

For difficult-to-grind samples such as high-tough plastics, high-strength plastics, and resins, cryogenic grinding can greatly improve the grinding effect and efficiency.


Features:

1. Does not destroy the sample components: the grinding temperature can be customized and adjusted, which can effectively inhibit nucleic acid degradation and retain protein activity;

2. Refrigeration adjustable: -50 to 37 degrees

3. High throughput throughput: process up to 192 samples at a time

4. Easy to operate: built-in program controller, can set parameters;

5. High safety: with safety cover and safety lock, no need to involve liquid nitrogen operation, high safety;

6. No cross-contamination: it is in a fully enclosed state during the grinding process to avoid cross-contamination;

7. Low noise: During the operation of the instrument, the noise is less than 55dB, which will not interfere with other experiments or instruments.

8. No wearing parts design, electromagnetic locking protection

9. Stainless steel inner cavity, easy to clean and disinfect

10. No need for regular maintenance

11. Stable repeatability: the same grinding procedure achieves the same effect

12. Program can be stored: 10 groups of custom grinding programs can be stored

13. Good grinding effect: discharge particle size 5um

The effect diagram of the grinding experiment case of the Cryogenic Grinder:

Product parameters:

Main parameters

Parameter range

Application

Tissue homogenization, grinding, cell disruption, homogenization, material dispersion, preparation, shaking

Sample processing:

The maximum throughput in 1.15 seconds can process 64 samples at the same time, suitable for 12-bit and 24-bit liquid nitrogen freezing adapters

Compatible sample size:

64*(0.2-0.5ML)/64*2ML/12*(5-15)ML/--4*25ML/2*50ML can be customized grinding tube of various specifications

Touch screen display:

Humanized interaction design, easy to operate

Store experimental data:

Ten groups of experimental data can be stored. According to different experimental samples, animal heart, spleen, lung, kidney, bone, skin, and hair patterns are set.

Pattern cycle:

According to the set experimental parameters, it can continuously cycle between several set parameters to further reduce the interference of human factors  

Maximum feed size:

No requirement, adjust according to adapter

Cooling function:

Yes, -50 degrees to room temperature

Temperature control accuracy

±0.5

Open cover operation protection:

Electromagnetic locking (switch optional manual or automatic)

Final discharge size:

~5μm

Number of grinding platforms:

Acceptable grinding jars: >2

Fastening device:

Fastening device with automatic centering

Homogenization speed and speed:

0一70HZ/s

Working hours:

0 seconds-9999 seconds, users can set by themselves

Grinding Ball Diameter:

0.1-30mm

Grinding Ball Material:

Alloy steel, chrome steel, zirconia, tungsten carbide, quartz sand

Accelerate:

Reach max speed in 2 seconds

Decelerate:

Reach minimum speed in 2 seconds

Noise level

<55db

Grinding method:

Wet grinding, dry grinding, cryogenic grinding

Cooling function

It has the function of upgrading to ultra-low temperature liquid nitrogen refrigeration or air refrigerator refrigeration

Adapter Material: 

PTFE or alloy steel

Full protection:

Safety lock when working

Grinding Kit Material:

Hardened steel, Teflon, Zirconia

Dimension

685*400*510MM

Weight

85KG

Optional accessories:

2025.12.15
冻台冷冻研磨仪赋能疾控:高效研磨蚊子样品,精准助力疾病防控
净信冻台冷冻研磨仪以标准化、自动化的研磨方案,助力疾控中心构建更快速的蚊媒病毒响应体系。
2025.12.08
攻克高粘弹性样品难题:高速冷冻研磨均质仪实现软糖高效精细粉碎
软糖通常具有粘性和弹性,这使得它们在研磨过程中容易粘在一起,难以粉碎成细小的颗粒。并且软糖对温度较为敏感,在研磨过程中,由于摩擦生热,软糖可能会熔化或变得更加粘稠,从而影响研磨效果。为了克服这些难点,我们选择了上海净信的高速冷冻研磨均质仪来完成此次实验。
2025.12.01
冷冻研磨仪赋能小鼠视网膜研磨实验:高效低温方案,保障样品活性与实验效率
实验目的:小鼠视网膜研磨,本次实验对象为小鼠视网膜组织,作为较小的组织,研磨起来也是一个难点,要求研磨彻底,以便提高蛋白及RNA的浓度,涉及到蛋白、RNA提取还需要低温研磨,因为有提取液,所以温度也不能太低,否则冻住液体无法研磨,经过比较推荐,最终客户选择上海净信的冷冻研磨仪处理样品。
2025.11.17
净信冷冻研磨仪:电路板材料研磨的“破冰”利器
如何才能完成电路板样品的前处理呢?净信冷冻研磨仪的出现,为电路板材料的样品前处理提供了一套解决方案。它利用“低温冷冻”与“高速撞击”相结合的独特原理,克服了传统方法的弊端,展现出以下优势。
2025.11.10
从“硬骨头”到“细粉末”,净信液氮冷冻研磨仪让实验更高效!
骨骼因其坚硬、致密的特性,一直是样品前处理中一块难啃的“硬骨头”。面对这一难题,净信全自动浸入式液氮冷冻研磨仪应运而生,它以其独特的设计理念,为骨骼样品处理带来了革命性的解决方案。
2022.01.19
增强型冷冻研磨仪操作视频+研磨效果图-上海净信
制冷可调节,降温速度快,研磨通量大,研磨效果好,不破坏样品成分,全封闭研磨,重复性稳定,程序可储存
2022.01.19
三维冷冻研磨仪JXCL-3K操作视频-上海净信
研创的双电机冷冻震荡一体化设计,多年成熟开发的低温高速破碎功能,轻松研磨研磨,专业高效
询价留言
*名称:

单位名称:
*电话:
*联系人:
*城市:
*验证码:
Baidu
map